assumed that the bit with status 1 (ON) shown is the highest bit that is ON in
the word.
00000
DMPX(77)
010
HR 20
#0010
LR 10
HR 20
#0012
IR 010
01000
:
01011 1
01012 0
: : :
01015 0
LR 10
LR 1000
LR 1001 1
LR 1002 0
: : :
: : :
LR 1015 0
Digit 0
IR 011
01100
:
01109 1
01110 0
: : :
01115 0
Digit 1
Digit 2
Digit 3
B
9
1
8
LR 11
LR 1100
:
LR 1108 1
LR 1109 0
: : :
LR 1115 0
HR 20
DMPX(77)
Address Instruction Operands
00000 LD 00000
00001 DMPX(77)
010
HR 20
# 0010
00002 DMPX(77)
LR 10
HR 20
# 0012
5-16-9 7-SEGMENT DECODER – SDEC(78)
S: Source word (binary)
IR, SR, AR, DM, HR, TC, LR
Di: Digit designator
IR, AR, DM, HR, TC, LR, #
Ladder Symbols
Operand Data Areas
D: First destination word
IR, AR, DM, HR, LR
SDEC(78)
S
Di
D
@SDEC(78)
S
Di
D
Di must be within the values given below
All destination words must be in the same data area.
When the execution condition is OFF, SDEC(78) is not executed. When the
execution condition is ON, SDEC(78) converts the designated digit(s) of S
into the equivalent 8-bit, 7-segment display code and places it into the desti-
nation word(s) beginning with D.
Any or all of the digits in S may be converted in sequence from the desig-
nated first digit. The first digit, the number of digits to be converted, and the
Limitations
Description
Data Conversion Section 5-16